| Type of fuel | #1 Oil - #2 Oil |
| Recommended surface | Up to 1600 sq. ft. (149 sq. m.) |
| Color | Metallic black |
| Exterior dimensions | 26"W x 25"D x 29"H |
| Maximum input (oil #1) | 39800 BTU |
| Maximum input (oil #2) | 33500 BTU |
| Minimum input (oil #1) | 10800 BTU |
| Minimum input (oil #2) | 11000 BTU |
| Efficiency | 73% |
| Maximum consumption (oil #1) | 1,08 l/h (0,28 gallon/h) |
| Maximum consumption (oil #2) | 0,9 l/h (0,24 gallon/h) |
| Minimum consumption (oil #1) | 0,3 l/h (0,08 gallon/h) |
| Minimum consumption (oil #2) | 0,3 l/h (0,08 gallon/h) |
| Exhaust pipe diameter | 5" |
| Type of chimney | Type A or type L |
| Recommended chimney diameter | 5" |
| Minimum chimney height | 16,5' |
| Type of burner | OCI |
| Type of carburator | OCI |
| Type of door | Glass with steel frame |
| Minimum clearances (Back) | 10" |
| Minimum clearances (Sides) | 10" |
| Minimum clearances (Corners) | 6" |
| Minimum clearances (Top) | 36" |
| Glass surface | 21 5/8"W x 11 3/8"H |
| Weight | 215 lbs (98 kg) |
| Warranty | Limited lifetime |
| Test standard - safety | CAN/CSA B140-3, UL 896 |
| Minimum draft required | 0,06 INWC with #1 oil, 0,05 INWC with #2 oil |